13-year testing machine production organization
Improve quality with cutting-edge technology, Product testing experts around youIndustry trends
-
022026-11
Drop Test Standards: ISTA 3A vs ASTM D5276
Three standards dominate carton drop testing, and they disagree on the details that matter most: drop height, the number of drops, and which faces are hit. Using the wrong one produces a report that looks complete but does not answer the buyer's question.ISTA 3AA distribution-oriented procedure for parcel delivery. Drop height is derived from package weight, and the sequence includes drops on edges and corners, not just faces. If th··· Learn more -
022026-11
Chamber Volume for IEC 60068-2-1 Tests
Buying a temperature chamber by volume alone is the most common specification mistake we see. The number on the datasheet describes the internal space — not the space your samples can actually occupy.The working volume ruleAir has to circulate around the load for the chamber to hold uniformity. As a rule of thumb, the samples should not fill more than one third of the internal volume, and they should not touch the walls or block the ai··· Learn more -
022026-11
UN38.3 T.4 & T.5: Crush and Impact Tests
UN38.3 is the transport-safety test series every lithium cell and battery pack must pass before it can fly. Two of its eight tests — T.4 crush and T.5 impact — are the ones most often failed on the first attempt, and both are decided by set-up rather than by the machine alone.T.4 crushA cell is crushed between two flat plates at 13 kN with a displacement rate not exceeding 0.1 mm/s. The pass criterion is no fire and no explosion. The ··· Learn more